Y Normal Pressure Gauge
YN Shockproof Pressure Gauge
Y-B Stainless Steel Pressure Gauge, Y-B-Z stainless steel shockproof Pressure Gauge
Location style pressure gauge
YTT Differential Transmissible Pressure Gauge, YTT-Z shockproof Differential Transmissible Pressure Gauge
YSG Inductance Pressure Transmitter
Y-M Diaphragm Seal pressure Gauge
PD-H-L Pressure Relay (Pressure controller)
YTXC-Z Shockproof Electric Contact Pressure Gauge
YXD-Z Photo electricity Shockproof Electric Contact Pressure Gauge
YXXD-Z Shockproof Photo electricity Signal Electric Contact Pressure Gauge
YP Diaphragm Pressure Gauge
YE-B Stainless Steel Capsule Pressure Gauge
YE Capsule Pressure Gauge
WS Bimetallic thermometer
CYS-150-Z Shockproof differential pressure gauge
YXC-J YXC-JA Protect relay
YXC-150-ZG Shockproof electric contact pressure gauge (high power)
YXG-100-B, YXG-150-B Explosion-proof pressure gauge with induction type contact
YXG-150-Z shockproof pressure gauge with induction type contact
YXG-K Controller
YXG-150-KG Induction type contact pressure gauge (with switch enlarger)
YXC-150J-Z,YXC-150JA-Z Shockproof electric contact pressure gauge (with protect relay)
YXH-100-Z,YXH-150-Z Shockproof magnetic induction electric contact pressure gauge
YSZC-4 Delicacy transmitter
YSZC-5 Standard transmitter
YSZC-6 Wind-pressure transmitter
Type of contacts & control mode£º                                                           table one
Model Schematic diagram Type of contact Location of control strip varies with motion of indicating needle Equivalent touch type contact
YXG-¡õ-B21 Upper limit, lower limit 1. Both control strips are located inside the induction switch
2. When indicating needle moves upstream (or downstream), control strip of upper limit contact (or lower
limit contact) withdraws from the induction switch
1.Both contacts are open.
2. Upper limit contact (lower limit contact) closes.
YXG-¡õ-B11 Double upper limit 1. Both control strips are located inside the induction switch.
2. When indicating needle moves upstream, control strip of contact 1 & 2 successively withdraws (leaves) from the induction switch
1. Both contacts are open.
2. Contact 1 & 2 successively closes.
YXG-¡õ-B22 Double lower limit 1. Both control strips are located inside the induction switch.
2. When indicating needle moves downstream, control strip of contact 2 & 1 successively withdraws (leaves) from the induction switch.
1. Both contacts are open.
2. Contact 2 & 1 successively closes.
YXG-¡õ-B1 yxg150b_3.jpg (6645 ×Ö½Ú) Single upper limit 1. Control strip is located inside the induction switch.
2. When indicating needle moves upstream, control strip of contact withdraws (leaves) from the induction switch.
1. Contact is open.
2. Contact is closed.
YXG-¡õ-B2 Single lower limit 1. Control strip is located inside the induction switch.
2. When indicating needle moves downstream, control strip of contact withdraws (leaves) from the induction switch.
1. Contact is open.
2. Contact is closed.
Note: In the schematic diagram:
Control strip is inside the induction switch, it indicates that the contact is under open state (contact current ¡Ül mA).
Control strip is outside the induction switch, it indicated that the contact is under closed state (contact current ¡Ý3mA).
100, 150
Dimension:

table two

Model D1 D2 L1 L2
YXG-100-B 100 100 88 94
YXG-150-B 150 161 90 126

< BACK > < NEXT >

¡¡


¡¡