Y Normal Pressure Gauge
YN Shockproof Pressure Gauge
Y-B Stainless Steel Pressure Gauge, Y-B-Z stainless steel shockproof Pressure Gauge
Location style pressure gauge
YTT Differential Transmissible Pressure Gauge, YTT-Z shockproof Differential Transmissible Pressure Gauge
YSG Inductance Pressure Transmitter
Y-M Diaphragm Seal pressure Gauge
PD-H-L Pressure Relay (Pressure controller)
YTXC-Z Shockproof Electric Contact Pressure Gauge
YXD-Z Photo electricity Shockproof Electric Contact Pressure Gauge
YXXD-Z Shockproof Photo electricity Signal Electric Contact Pressure Gauge
YP Diaphragm Pressure Gauge
YE-B Stainless Steel Capsule Pressure Gauge
YE Capsule Pressure Gauge
WS Bimetallic thermometer
CYS-150-Z Shockproof differential pressure gauge
YXC-J YXC-JA Protect relay
YXC-150-ZG Shockproof electric contact pressure gauge (high power)
YXG-100-B, YXG-150-B Explosion-proof pressure gauge with induction type contact
YXG-150-Z shockproof pressure gauge with induction type contact
YXG-K Controller
YXG-150-KG Induction type contact pressure gauge (with switch enlarger)
YXC-150J-Z,YXC-150JA-Z Shockproof electric contact pressure gauge (with protect relay)
YXH-100-Z,YXH-150-Z Shockproof magnetic induction electric contact pressure gauge
YSZC-4 Delicacy transmitter
YSZC-5 Standard transmitter
YSZC-6 Wind-pressure transmitter
YXG-150-Z shockproof pressure gauge with induction type contacts

       The gauge features: resistance to environmental vibrations and withstanding pulsation of
medium and load's striking. It adopts contact-less induction switch. Its electric signal convertible
equipment, sensibility high, control precision high and respondence quickly. It has no laggardly leap
phenomena. Switch features are good. It is formed a complete set of YXG-K.

Specification£º
Design£º Q/320211 DGH08-2002
Accuracy£º1.6
Scale range£º0-0.16,0-0.25,0-0.4,0-0.6,0-1.0,0-1.6,0-2.5,0-4.0,0-6.0,0-10,0-16,0-25.0-40,0-60,-0.1-0.15,-0.1-0.3,-0.1-0.5,-0.1-0.9,-0.1-1.5,-0.1-2.4MPa
Working temperature£º-10¡æ~ 55¡æ¡£
Protection degree£ºIP54
Electric parameters£º working voltage 8V DC
         working current: I on ¡Ý3mA, I off ¡Ü1mA

Type of contact and control mode£º

table 1

Model

Schematic diagram

Type of contact Location of control strip varies with motron of indicating needle Equivalent touch type contact
YXG-150-Z21

¡¡

Upper limit, lower limit 1.Both control strips are located inside the induction switch
2. When indicating needle moves upstream (or downstream), control strip of upper limit contact (or lower
limit contact) withdraws from the induction switch.
1.Both contacts are open, output high impedance.
2.Upper limit contact (lower limit contact) closes, output low impedance.
YXG-150-Z11 Double upper limit 1.Both control strips are located inside the induction switch.
2.When indicating needle moves upstream, control strip of contact land 2 successively withdraws (leaves) from the induction switch.
1.Both contacts are open, output high impedance.
2.Contact 2 and 1 successively closes, output low impedance.
YXG-150-Z22 Double lower limit 1.Both control strips are located inside the induction switch.
2.When indicating needle moves downstream, control strip of contact 2 and 1 successively withdraws (leaves)
from the induction switch.
1.Both contacts are open, output high impedance.
2.Contact 2 and 1 successively closes, output low impedance.
YXG-150-Z1 Single upper limit 1.Control strip is located inside the induction switch.
2. When indicating needle moves upstream, control strip of contact withdraws (leaves) from the induction switch.
1.Contact is open, output high impedance.
2.Contact is closed, output low impedance.
YXG-150-Z2 Single lower limit 1.Control strip is located inside the induction switch.
2. When indicating needle moves downstream, control strip of contact withdraws (leaves) from the induction switch.
1.Contact is open, output high impedance.
2.Contact is closed, output low impedance.

Note£º in the schematic diagram:
       
   Control strip is inside the induction switch, it indicates that the contact is under open state.
        
   Control strip is outside the induction switch, it indicates that the contact is under closed state.