Y Normal Pressure Gauge
YN Shockproof Pressure Gauge
Y-B Stainless Steel Pressure Gauge, Y-B-Z stainless steel shockproof Pressure Gauge
Location style pressure gauge
YTT Differential Transmissible Pressure Gauge, YTT-Z shockproof Differential Transmissible Pressure Gauge
YSG Inductance Pressure Transmitter
Y-M Diaphragm Seal pressure Gauge
PD-H-L Pressure Relay (Pressure controller)
YTXC-Z Shockproof Electric Contact Pressure Gauge
YXD-Z Photo electricity Shockproof Electric Contact Pressure Gauge
YXXD-Z Shockproof Photo electricity Signal Electric Contact Pressure Gauge
YP Diaphragm Pressure Gauge
YE-B Stainless Steel Capsule Pressure Gauge
YE Capsule Pressure Gauge
WS Bimetallic thermometer
CYS-150-Z Shockproof differential pressure gauge
YXC-J YXC-JA Protect relay
YXC-150-ZG Shockproof electric contact pressure gauge (high power)
YXG-100-B, YXG-150-B Explosion-proof pressure gauge with induction type contact
YXG-150-Z shockproof pressure gauge with induction type contact
YXG-K Controller
YXG-150-KG Induction type contact pressure gauge (with switch enlarger)
YXC-150J-Z,YXC-150JA-Z Shockproof electric contact pressure gauge (with protect relay)
YXH-100-Z,YXH-150-Z Shockproof magnetic induction electric contact pressure gauge
YSZC-4 Delicacy transmitter
YSZC-5 Standard transmitter
YSZC-6 Wind-pressure transmitter
YXG-150-KG Induction type contact pressure gauge (with switch enlarger)

       The gauge adopts contact-less induction switch, no contact corrosion phenomena, sensibility high, respondence quickly and control precision high. It has no laggardly leap phenomena, safety and trustworthy. There are two switch enlargers in the gauge. And the gauge outputs 0.3V¡«24V high-low voltage signal that is used to process control, and is used to drive small power load.

Specification£º
Design£º Q/320211 DGH08-2002
Accuracy£º1.6
Scale range£º0-0.16,0-0.25,0-0.4,0-0.6,0-1.0,0-1.6,0-2.5,0-4.0,0-6.0,-0.1-0.15,-0.1-0.3,-0.1-0.5,-0.1-0.9,-0.1-1.5,0.1-2.4MPa
Ambient temperature£º-10¡æ-55¡æ
Protection degree£ºIP54
Voltage£ºDC24V; Current£º100mA max.
Output£º high-low voltage£º0.3V/24V; Current£º¡Ü30mA¡£

Type of contact and control mode£º
  
Model

Schematic diagram

Type of contact

Location of control strip varies with motion of indicating needle

Equivalent touch type contact

YXG-150-KG21 Upper limit, lower limit 1. Both control strips are located inside the induction switch
2. When indicating needle moves upstream (or downstream), control strip of upper limit contact (or lower
limit contact) withdraws from the induction switch
1.Both contacts are open, output low voltage.
2. Upper limit contact (lower limit contact) closes,
output high voltage.
YXG-150-KG11 Double upper limit 1. Both control strips are located inside the induction switch.
2. When indicating needle moves upstream, control strip of contact 1 & 2 successively withdraws (leaves) from the induction switch
1. Both contacts are open, output low voltage.
2. Contact 1 & 2 successively closes
, output high voltage.
YXG-150-KG22 Double lower limit 1. Both control strips are located inside the induction switch.
2. When indicating needle moves downstream, control strip of contact 2 & 1 successively withdraws (leaves) from the induction switch.
1. Both contacts are open, output low voltage.
2. Contact 2 & 1 successively closes
, output high voltage.
YXG-150-KG1 Single upper limit 1. Control strip is located inside the induction switch.
2. When indicating needle moves upstream, control strip of contact withdraws (leaves) from the induction switch.
1. Contact is open, output low voltage.
2. Contact is closed
, output high voltage.
YXG-150-KG2 Single lower limit 1. Control strip is located inside the induction switch.
2. When indicating needle moves downstream, control strip of contact withdraws (leaves) from the induction switch.
1. Contact is open, output low voltage.
2. Contact is closed,
output high voltage.

Note: In the schematic diagram:
          Control strip is inside the induction switch, it indicates that the contact is under open state .
         
Control strip is outside the induction switch, it indicates that the contact is under closed state.

< NEXT >

¡¡¡¡


¡¡