YXC-150J-Z,YXC-150JA-Z
Shockproof electric contact pressure gauge (with
protect relay)
The gauge
features: withstanding pulsation of medium and
loading's striking, and resistance to environmental
vibrations, suitable for measuring pressure of
gases, liquids none corrosive copper and the alloy
of copper and steam. It equipped with a maximum and
minimum connection switch mechanism, so that when
the pressure reaches a predeterminate value, the
instrument would emit a signal or severe the
electrical connection, used for automation and
signally purpose. The shockproof structure
effectively controls the needles shaking rushing and
protects the connection points. So to allow the
instrument to display clearly, send reliable signals
and function stably.
The gauge's contact power is small, and filling oil
can extend its measuring system's life, but the
contact's contact resistance increased because of
the oil. The contact is easy to suffer losses. It is
not fit for low voltage (high current) open busy.
The gauge with protect relay can effectively solve
by the aforementioned defects. Protect relay
provides small working current for the contact. The
contact's open and close make the protect relay
working. The protect relay's switch enlarge circuit
can solve the effect of contact resistance, makes
the contact trustworthy, protects the contact
completely, can increase the contact's electric
life. The output of import relay can take very high
lead. It is satisfied to the gauge's working demand
( low voltage, high current).
It's widely suitable for mechanical, chemical,
petrol, extraction mining, electric power industrial
production processes.
Specification£º
|
Scale
range MPa |
-0.1¡«0.15£»-0.1¡«0.3£»-0.1¡«0.5£»-0.1¡«0.9£»-0.1¡«1.5£»-0.1¡«2.4£»
0¡«0.25£»0¡«0.4£»0¡«0.6£»0¡«1.0£»0¡«1.6£»0¡«2.5£»0¡«4.0£»0¡«6.0£»0¡«10£»0¡«16£»0¡«25£»0¡«40£»0¡«60£» |
|
Accuracy % |
¡À1.6 |
|
Operational
condition |
YXC-150J-Z |
Source DC24V£¬Power 1.1W |
|
YXC-150JA-Z |
Source AC220V£¬Power 1.2VA |
|
Output contact
(Resistance load) |
Max.
Operational voltage |
AC380V£¬DC125V |
|
Rated load |
AC250V/8A£¬DC30V/8A |
|
Electric life: 105 switches,
Machine life: 107 switches |
Design: Q/320211 DGH05-2004
Operational temperature: -25¡æ¡«55¡æ
Operational maximum pressure: does not exceed 2/3 of
the gauge's maximum
Operational environments must have vibration
frequency less than 25Hz and amplitude less than
0.5mm.
Dimension:

<
NEXT
> ¡¡ ¡¡ |